Importatore unico per l'Italia dei prodotti Davis Instruments
0522 969177 -
info@salvarani.com
|

Carrello

 

Contatti

 

Salvarani S.r.l.

via M. Buonarroti, 2
42028 Poviglio (RE) - Italy
Lat. 44.837812, Long. 10.546703
Tel: +39 0522 969 177 
(lun-ven, 8-12, 13:30-17:30)
Fax: +39 0522 960 612
simone.m@salvarani.it

Modulo Modbus TCP/IP per stazioni Davis

 
Modbus TCP/IP KTA-282 per stazioni Davis
Interfaccia Modbus TCP/IP per stazioni Davis Vantage Pro2 dotate di datalogger seriale
Prezzo
€ 320,00 + iva
Disponibilità
4
Codice
DW-KTA-282
Quantità
  

Il modulo Modbus KTA-282 TCP Weather Station Gateway è un upgrade del modello GWY-141 (serial modbus gateway) con l'aggiunta della funzionalità Modbus TCP/IP.

The gateway allows you to easily connect your PLC (Programmable Logic Controller), RTU (Remote Telemetry Unit) or SCADA (Supervisory Control And Data Aquisition) System to one of the following Davis weather stations:

6152CEU Cabled Vantage Pro 2

6162CEU Cabled Vantage Pro 2 Plus

6152EU  Wireless Vantage Pro 2

6162EU Wireless Vantage Pro 2 Plus

6153EU Wireless Vantage Pro 2 Fan Aspirated

6163EU Wireless Vantage Pro 2 Plus Fan Aspirated

6316EU Wireless Weather Envoy (with Wireless ISS, ISS Plus, ISS Solar Fan Aspirated or ISS Plus Solar Fan Aspirated)

6250EU Vantage Vue

The gateway plugs into the weather station's console using the Davis WeatherLink cable (Weather Link for Vantage Pro Serial) and appears on the Modbus network as a Modbus TCP/IP or RTU slave. This allows your programmable controller to monitor and carry out actions based on wind speed, wind direction, temperature, etc.

Features:

  • New! Two Open Collector outputs for alarms or control
  • Connects to a Modbus TCP/IP network via Ethernet. Can be polled by up to three Modbus masters simultaneously
  • Provides a webpage whereby TCP/IP settings can be easily configured. Also shows current settings, weather data, and communications statuses
  • Also supports Modbus RTU over RS-485.
  • Supports the new LOOP 2 command. This provides an additional 16 packets of previously unavailable weather data.
  • Can directly write the internal memory of the weather station, allowing configuration values to be changed (commonly latitude, longitude, elevation, timezone, etc)
  • Allows interrogation over HTTP to return any Modbus register values in XML format. Make your own custom application using the weather data
  • The unit can be screwed to a panel, or mounted to DIN rail.
  • Dimensions: 115 × 90 × 40 mm
  • 8 to 28V DC powered; 100mA

Documentazione

Manuale Modulo Modbus TCP/IP KTA-282
Download

Articoli correlati

Modulo Modbus per stazioni Davis
Modulo Modbus per stazioni Davis