Importatore unico per l'Italia dei prodotti Davis Instruments
0522 969177 -
info@salvarani.com
|

Carrello

 

Contatti

 

Salvarani S.r.l.

via M. Buonarroti, 2
42028 Poviglio (RE) - Italy
Lat. 44.837812, Long. 10.546703
Tel: +39 0522 969 177 
(lun-ven, 8-12, 13:30-17:30)
Fax: +39 0522 960 612
simone.m@salvarani.it

Modulo Modbus per stazioni Davis

 
Interfaccia Modbus per stazioni Davis Vantage Pro2 dotate di datalogger seriale
Prezzo
€ 230,00 + iva
Disponibilità
4
Codice
DW-GWY-141
Quantità
  
Interfaccia Modbus per stazioni Davis Vantage Pro2 dotate di datalogger seriale (DW-6510SER).
NB: Se necessitate di una comunicazione Modbus TCP/IP, vi consigliamo l'upgrade KTA-282 (click qui!)

Description:
Our Modbus to Davis Vantage Pro2 Weather Station Gateway allows you to easily connect your PLC (Programmable Logic Controller), RTU (remote telemetry unit) or SCADA System to one of the following Davis weather stations:

6152 Cabled Vantage Pro 2
6162 Cabled Vantage Pro 2 Plus
6152 Wireless Vantage Pro 2
6162 Wireless Vantage Pro 2 Plus
6153 Wireless Vantage Pro 2 Fan Aspirated
6163 Wireless Vantage Pro 2 Plus Fan Aspirated
6316 Wireless Weather Envoy (with Wireless ISS, ISS Plus, ISS Solar Fan Aspirated or ISS Plus Solar Fan Aspirated)
The gateway plugs into the weather station's console using the Davis WeatherLink cable (Weather Link for Vantage Pro Serial) and appears on the Modbus network as a Modbus RTU slave. This allows your programmable controller to monitor and carry out actions based on wind speed, wind direction, temperature etc.

Features:
Now with metric conversion (V5.4)
Connects to weather station via RS-232 Com Port 2, Baud rate 19200 bps
Connects the Modbus RTU network via RS-232 or RS-485.
Modbus slave address selectable from 1 to 16.
Selectable Modbus RTU baud rate of 2400, 4800, 9600 or 19200 bps
Selectable Modbus RTU parity none, odd, even
Transfer readings:
Outdoor Temperature
Outdoor Humidity
Wind Speed
Wind Direction
Rainfall (Precipitation)
Barometric Pressure
Indoor Temperature (console)
Indoor Humidity (console)
Solar Radiation
Evaporative Transfer
Daily Rainfall
Weekly Rainfall
Monthly Rainfall
Communications OK status register shows the communications between the weather station and gateway is OK
The unit can be screwed to a panel or a clip allows mounting to a DIN rail.
Dimensions: 115 × 90 × 40 mm

Software:

NB: Se necessitate di una comunicazione Modbus TCP/IP, vi consigliamo l'upgrade KTA-282 (click qui!)

Documentazione

Manuale istruzioni interfaccia Modbus
Download

Articoli correlati

Modulo Modbus TCP/IP per stazioni Davis
Modulo Modbus TCP/IP per stazioni Davis